RECOMMENDED USES:
Split face Block Stucco
Smooth Block Cement Plaster
Adobe Block Slump Block
Brick Painted surfaces
Horizontal Concrete Chalked Surfaces
Vertical Concrete Aggregate Panels
Wood Natural Stone
Wall Board EFIS
Clay Roof Tiles Painted Surfaces
COVERAGE RATES (THEORETICAL):
Substrate ___ Sq Ft/ Gallon
Dense Masonry 100-150
Porous Masonry 60-100
Stucco/EFIS 150-200
Wood 175-200
Painted Surfaces 400
Notes: *Use of fluted or scored block or raked joints will
increase surface areas by 20%-30% or more and de-
crease coverage rates.
Warranty Period: Three Year Limited
USA
International
Part Numbers: 1 Gallon TPC-0201 TPC-0201-CA
5 Gallon TPC-0205 TPC-0205-CA
Wet Look
with Micro-LokTechnology
WetLook Gloss Masonry and Wood Sealer
PRODUCT DESCRIPTION
WET LOOK is a high solids, water based, modified silicone
acrylic water repellent and sealer that protects and beautifies
vertical and horizontal, interior and exterior masonry, concrete
and painted surfaces with a beautiful gloss/wet look finish.
Features and Benefits:
Gloss finish repellent and alkali resistant sealer for masonry
and concrete
Protects and beatifies surfaces with a wet look finish
For use on interior and exterior surfaces
Resists flaking and has excellent adhesion
Protection not effected by weathering or UV light
Excellent wear and abrasion resistance
Virtually maintenance free
Breathable does not trap moisture
HOW TO USE
WET LOOK is supplied ready to use. DO NOT THIN. Mix
thoroughly prior to use. Avoid application in windy weather.
In hot weather, lightly dampen surfaces with clean fresh water
to avoid premature or flash drying.
Porous Vertical Surfaces
Start first coat application at the top of the wall. Apply flood
coat with a 6-8 rundown and back-roll material into surface
voids. Apply second coat when the first coat is dry.
Vertical Concrete Surfaces
Material may be applied as soon as the forms are removed.
Surfaces shall be clean and free of form oils and release agents.
Start first coat application at the top of the wall. Apply satura-
tion coat and back-roll materials. Apply second coat when the
first coat is dry. (Continued on back)
TECHNICAL DATA:
Solvent ` Water
Material Type Modified Silicone Acrylic
Active Solids Content Approximately 25.0%
Odor Low Odor
Appearance When Dry Dries to a Gloss Finish
V.O.C. <15 g/L
Flash Point None
Weight Approximately 8.7 lbs./gal.
Surface Dry Time Approx 1 Hr
Recoat Approx 1 Hour
Full Chemical Cure 72-96 Hours
Application Temp 45° to 90° F